AbstractAbstract
[en] I calculated neutron and gamma-ray equivalent doses leaking through a variety of infinite (laminate) slab-shields. In the shield computations, I used, as the incident neutron spectrum, the leakage spectrum (<20 MeV) calculated for the LANSCE tungsten production target at 90 degree to the target axis. The shield thickness was fixed at 60 cm. The results of the shield calculations show a minimum in the total leakage equivalent dose if the shield is 40-45 cm of iron followed by 20-15 cm of borated (5% B) polyethylene. High-performance shields can be attained by using multiple laminations. The calculated dose at the shield surface is very dependent on shield material. 4 refs., 4 figs., 1 tab
Primary Subject
Secondary Subject
Source
1989; 12 p; International collaboration on advanced neutron sources (ICANS); Los Alamos, NM (USA); 3-7 Oct 1988; CONF-8810182--33; CONTRACT W-7405-ENG-36; Available from NTIS, PC A03/MF A01 as DE90001826; OSTI; INIS; US Govt. Printing Office Dep