Dingman, S.E.; Kelly, J.E.
Sandia National Labs., Albuquerque, NM (USA)1989
Sandia National Labs., Albuquerque, NM (USA)1989
AbstractAbstract
[en] The MELCOR computer code, which has been developed at Sandia National Laboratories for the US Nuclear Regulatory Commission as a tool for calculating realistic estimates of severe accident consequences and source terms, has been used to analyze a series of containment issues for station blackout sequences for the Grand Gulf Nuclear Power Plant. The results indicate that there is a limited time interval in which the drywell atmosphere would be flammable, and that this would only occur if the vacuum breaker were to stick open within a narrow time window. If burning does occur during this time, it appears quite likely that it would not pose a threat to the drywell wall. The main conclusion from this study is that the drywell atmosphere is not very likely to be flammable for a station blackout sequence. 1 ref. (S.J.)
Primary Subject
Secondary Subject
Source
1989; 4 p; Winter meeting of the American Nuclear Society; San Francisco, CA (USA); 26-30 Nov 1989; CONF-891103--13; CONTRACT AC04-76DP00789; Available from NTIS, PC A02/MF A01 as DE89014132; OSTI; INIS; US Govt. Printing Office Dep
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue