AbstractAbstract
[en] The use of the Kern Me5000 as a stand alone instrument is restricted to a minimum measurement distance of approximately 20m (Kern internal low range program), with a display readout to the nearest 100μm. Using an external program, it is possible to extend both, the display resolution to 10μm, and the range down to distances well below 20m. This paper attempts to explain Kern's reasoning behind the original limitation of approximately 20m, and presents the results from testing three Mekometer Me5000 instruments. Their similarities, differences, and accuracies are assessed for distances below 25m providing a comparison against the use of invar wires
Primary Subject
Secondary Subject
Source
Stanford Linear Accelerator Center, Menlo Park, CA (United States); 322 p; Oct 1990; p. 171-183; 1. international workshop on accelerator alignment; Stanford, CA (United States); 31 Jul - 2 Aug 1989; CONF-8907190--; OSTI as DE91007297; NTIS; INIS
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue