AbstractAbstract
[en] A radiotracer method has been developed to characterize new fuel-cell membrane materials having high ionic conductance. Three radiotracers were employed simultaneously in cell studies and measured by a combination of liquid-scintillation and gamma-ray counting. This new method has been shown capable of measuring equilibrium concentrations and transport rates of sodium cations (representing counterions), chlorine anions (representing colons), and water molecules in ion-exchange membranes
Source
2. topical meeting on industrial radiation and radioisotope measurement applications; Raleigh, NC (United States); 8-11 Sep 1992; CONF-920919--
Record Type
Journal Article
Literature Type
Conference
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume