AbstractAbstract
[en] Long-term body retention was measured on six workers inhaling 60Co aerosols incidentally during manipulation with a high activity 60Co source. An improved whole body counter technique and calibration provided good conditions to follow the body clearance over 4 years. A two-detector profile scanning arrangement was used to measure the activity distribution 'in vivo' over the lung region. The observed whole body retention followed a two-exponential time function between 10-1500 days. The consistency of the measured retention pattern with ICRP inhalation model was investigated assuming different aerosol size distributions. A possible extension of ICRP lung model is proposed to take into account the actual pulmonary lung clearance determined individually. (R.P.) 29 refs.; 15 figs.; 6 tabs
Primary Subject
Source
Mar 1993; 42 p
Record Type
Report
Report Number
Country of publication
ACCIDENTS, AEROSOLS, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CLEARANCE, COBALT ISOTOPES, COLLOIDS, COUNTING TECHNIQUES, DISPERSIONS, EXCRETION, INTAKE, INTERMEDIATE MASS NUCLEI, INTERNAL CONVERSION RADIOISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, MINUTES LIVING RADIOISOTOPES, NUCLEI, ODD-ODD NUCLEI, RADIOISOTOPES, SOLS, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue