AbstractAbstract
[en] CEBAF's production cavities are tested in a vertical configuration after appropriate chemical surface treatment prior to installation into the accelerator. The performance of these cavities is excellent, often exceeding the specifications of Eacc=5 MV/m at 2 K by factors of 2 to 3. In such cases the cavities are often limited by thermal-magnetic breakdown. A cavity that exhibited a limiting gradient of Eacc ≤ 16.4 MV/m has been heat-treated at 1400 degrees C for 6 hours in the presence of titanium as a solid state gettering material to improve the thermal stability of the niobium. After the heat treatment a gradient of Eacc=20.5 MV/m corresponding to a peak surface electric field of Epeak=52 MV/m has been measured. In addition to the cavity results, data on thermal conductivity and tensile properties of samples which have undergone the same treatments as the cavity are reported
Primary Subject
Source
Jun 1993; 3 p; CEBAF-PR--93-023; CONTRACT AC05-84ER40150; Also available from OSTI as DE93017915; NTIS; US Govt. Printing Office Dep