Sygitowicz, L.S.; Bastian, C.T.; Wells, I.J.; Koch, P.N.
Eleventh DOE workshop on personnel neutron dosimetry1991
Eleventh DOE workshop on personnel neutron dosimetry1991
AbstractAbstract
[en] Historically, neutron dosimetry at the NTS was done using NTA film and albedo LiF TLD's. In 1987 the dosimeter type was changed from the albedo TLD based system to a CR-39 track etch based system modeled after the program developed by D. Hankins at LLNL. Routine issue and return is performed quarterly for selected personnel using bar-code readers at permanent locations. The capability exists for work site issue as-needed. Issue data are transmitted by telephone to a central computer where it is stored until the dosimeter is returned, processed and read, and the dose calculation is performed. Dose equivalent calculations are performed using LOTUS 123 and the results are printed as a hard copy record. The issue and dose information are hand-entered into the Dosimetry database. An application is currently being developed to automate this sequence
Primary Subject
Source
USDOE Assistant Secretary for Environment, Safety, and Health, Washington, DC (United States). Office of Health; 182 p; 1991; p. 9-11; 11. Department of Energy workshop on personnel neutron dosimetry; Las Vegas, NV (United States); 4-7 Jun 1991; Available from OSTI as DE93013824; NTIS; INIS
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue