AbstractAbstract
[en] This document describes the computation of the buckling pressure of the primary liner of Tank 241SY101. It describes the calculation of the negative gauge pressure required to buckle the liner. A negative pressure may develop inside the tank when water is sprayed on the hydrogen mitigation pump during its removal. Calculations indicate that the liner will buckle at 23,442 Pa, or 239 cm of water
Primary Subject
Source
19 Dec 1994; 31 p; CONTRACT AC06-87RL10930; Also available from OSTI as DE95010229; NTIS; US Govt. Printing Office Dep
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume