AbstractAbstract
[en] The Parameter Display Page program (DP) is a Motif/X11-based program to allow easily configured, dynamic device and process variable monitoring and manipulation in the EPICS environment. DP provides a tabular data format for interactive viewing and manipulation of device and process variable statistics, as well as formatted PostScript output to files and printers. DP understands and operates in two (unfortunately disjoint at this time) namespaces in the EPICS environment ''devices'' and ''process variables''. The higher level namespace of devices includes Composite and Atomic Devices registered via the Device Access server; the lower level (flat) namespace is that of normal Process Variables accessible via Channel Access
Primary Subject
Secondary Subject
Source
19 Feb 1994; 3 p; CONTRACT W-31109-ENG-38; Also available from OSTI as DE96006133; NTIS; US Govt. Printing Office Dep