Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.016 seconds
AbstractAbstract
[en] This document provides the design rational for using a 5.08 by 5.08 cm (2 by 2 in.) sodium iodide detector to aid in boundary mapping of the radioactive contaminated soils at the Hanford Site. The detector can provide adequate response to a homogeneously contaminated soil volume of at least 1.22 to 1.52 m in diameter and up to 45.7 cm deep. The gamma activity basis is described by a soil column in a right circular cylinder that is uniformly isotopic. The detection techniques and characteristics are used to define contaminated areas requiring excavation by locating regions where gamma activities exceed cleanup standards. To determine the areas and boundary of contamination, the boundary and adjacent surfaces will be mapped using the detector operated in a windowed gross-gamma mode
Secondary Subject
Source
Jul 1996; 27 p; CONTRACT AC06-93RL12367; Also available from OSTI as DE97050378; NTIS; US Govt. Printing Office Dep