Bradley, J.T. III; Collins, M.
Los Alamos National Lab., NM (United States). Funding organisation: USDOE, Washington, DC (United States)1997
Los Alamos National Lab., NM (United States). Funding organisation: USDOE, Washington, DC (United States)1997
AbstractAbstract
[en] The klystron microwave amplifier tubes used in the Low Energy Demonstration Accelerator (LEDA) and to be used in the Accelerator Production of Tritium (APT) plant have a strict upper limit on the amount of energy which can be safely dissipated within the klystron's vacuum envelope during a high voltage arc. One way to prevent damage from occurring to the klystron microwave amplifier tube is through the use of a crowbar circuit which diverts the energy stored in the power supply filter capacitors from the tube arc. The crowbar circuit must be extremely reliable. To test the crowbar circuit, a wire that is designed to fuse when it absorbs a predetermined amount of energy is switched between the high voltage output terminals. The energy required to fuse the wire was investigated for a variety of circuits that simulated the power supply circuit. Techniques for calculating wire length and energy are presented along with verifying experimental data
Primary Subject
Source
1997; 7 p; 11. IEEE international pulsed power conference; Baltimore, MD (United States); 29 Jun - 2 Jul 1997; CONF-9706113--19; CONTRACT W-7405-ENG-36; Also available from OSTI as DE97008748; NTIS; US Govt. Printing Office Dep
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue