Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.02 seconds
Eto, Motokuni; Ishiyama, Shintaro; Fukaya, Kiyoshi; Saito, Tamotsu; Ishihara, Masahiro; Hanawa, Satoshi.
Japan Atomic Energy Research Inst., Tokyo (Japan)1998
Japan Atomic Energy Research Inst., Tokyo (Japan)1998
AbstractAbstract
[en] A concept and specifications of carbon/carbon composite (C/C) control rod were proposed, aiming at the application of the material to the HTTR. The outer diameter and length of the control rod were kept as the same as those of the present control rod, i.e., 113 mm and 3094 mm, respectively. According to the concept, the rod consists of ten units which are connected in series using bolts. Then, the stresses generated by dead loads in the control rod elements were estimated and compared with the design strengths which were derived from the results of measurements of tensile, compressive, bending and shear strengths of two candidate materials, AC250 (Across Co.) and CX-270 (Toyo Tanso Co.). Design strength was preliminarily determined as one-third or one-fifth of the mean strength. Ratio of the design strength to generated stress for the AC250 (2D) was : Tensile stress in the outer sleeve tube, 66, tensile and shear stresses in the M16 bolt, 8.8 and 8.5, shear stress in the plug support bolt M8, 2.43. These results are believed to indicate the mechanical integrity of the control rod structure. Data available on the candidate materials were also compiled in the Appendix. (author)
Primary Subject
Secondary Subject
Source
Jan 1998; 39 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume