AbstractAbstract
[en] Knolls Atomic Power Laboratory reported that the trip-initiated, problem-termination feature was not functioning in TRAC-P, Version 5.4.15. A listing of the modified input data for the DRAIN standard test problem and the TRCMSG file output was provided that demonstrated that the TRAC-P calculation did not terminate when the problem-termination designated trip's set status was set to ONforward. The assigned task was to investigate and correct this nonfunctioning feature in TRAC-P, Version 5.4.28. Update FXTPTM corrects a trip pointer error in subroutine TIMCHK that prevented the trip-initiated, problem-termination feature from functioning in TRAC-P