Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.035 seconds
AbstractAbstract
[en] Neutron Computed Tomography (N CT) is the nondestructive testing technique. Neutrons can interact with the light materials and can be distinguished between light materials and heavy materials as well. The good profile data were obtained from the television method using neutron beam from the research reactor. N CT images were reconstructed and displayed on IBM P C 80486 microcomputer with VGA color monitor by 64 gray levels. The convolution filter backprojection technique and Shepp-Logan filter function were selected for the reconstruction program
Primary Subject
Source
Office of Atomic Energy for Peace, Bangkok (Thailand); 761 p; Dec 1996; [11 p.]; 6. Conference on Nuclear Science and Technology; Bangkok (Thailand); 2-4 Dec 1996; ALSO AVAILABLE FROM OFFICE OF ATOMIC ENERGY FOR PEACE, BANGKOK (THAILAND)