AbstractAbstract
[en] In order to confirm the measurement accuracy of PIXE (Particle Induced X-ray Emission), cross-check test were carried out between three laboratories. Thirty single element samples and one plural elements sample were used in the test. The agreements between three laboratories were evaluated to be better than 10% for the most of tested samples. The reproducibility test showed very good agreement and the dispersion in three times repeated PIXE measurements was within 6% on average. Using an automatic time sequence step sampler in Beijing collected atmospheric aerosol samples. Element concentrations were analyzed by PIXE technique. Then the data were analyzed by the absolute principal factor analysis (APFA) to evaluate the principal components and the percent variance explained by them. As a result, it shows that the PIXE analysis combed with statistical method can effectively resolve the aerosol components in urban area and distinguish between local and remote area aerosol components. The atmospheric aerosol samples were collected at four representative sites with an 8-stage cascade impactor sampler and analyzed for their elemental mass concentrations by PIXE analytic method. Based on some indicator elements, the characteristics of size distributions of particles from different sources were obtained
Primary Subject
Source
Nov 1998; 14 p; LENP--0006; 18 refs., 3 figs., 6 tabs.