AbstractAbstract
[en] The evaluation of material integrity on electricity generator component has been done. That component was main steam pipe of Unit II Suralaya Coal Fired Power Plant. evaluation was done by replication technique. The damage was found are two porosity's, from two point samples of six points sample population. Based on cavity evaluation in steels, which proposed by Neubauer and Wedel that porosity's still at class A damage. For class A damage, its means no remedial action would be required until next major scheduled maintenance outage. That porosity's was grouped on isolated cavities and not need ti repair that main steam pipe component less than three year after replication test
Original Title
Penilaian keutuhan material pada komponen siklus uap air pembangkit listrik (Pipa Uap Utama)
Primary Subject
Secondary Subject
Source
Reactor Safety Technology Research Center, National Atomic Energy Agency, Serpong (Indonesia); 218 p; ISSN 1410-0533;
; 1998; p. 201-212; 3. Scientific Presentation on Reactor Safety Technology; Presentasi Ilmiah Teknologi Keselamatan Reaktor III; Serpong (Indonesia); 13-14 May 1998; Authors; 3 refs; 1 tab; 11 figs