[en] After the Cu and Ni ion implantation and subsequent high-current electron beam (HCEB) treatment, Ti41-V41-Al18 alloy is investigated. After the Cu, Ni implantation and HCEB treatment, this fatigue limit increases by 60%, the subsequent furnace annealing increases it by 90%. Hardness also increases and the friction coefficient decreases by a factor of 1.8 after this double implantation and HCEB treatment
Original Title
Zmyini mekhanyichnikh vlastivostej splavu Ti-V-Al pyislya yionnoyi yimplantatsyiyi Cu yi Ni ta obrobki sil'nostrumovim elektronnim puchkom