AbstractAbstract
[en] To determine detection capabilities of locating of steel bars inside concrete, commercially available Nondestructive Testing(NDT) equipments have been tested. The equipments include two radar systems and one eletromagnetic method system. The inclusions are 13, 16, 19, 25 and 55 mm diameter steel bar, φ30 mm PVC pipe, φ50 mm sheath, wood(2x10 cm), styrofoam(2x10 cm) and water container(15x30 cm) embedded at different cover depths from the surface of concrete specimens. And, the horizontal spacing of steel bars are varied ranging from 5 to 35 cm to determine the horizontal spacing of them. Experimental results on various measurement cases are discussed. From this study, it is proved that radar measurements is good to detection of locating and spacing of steel bars and electromagnetic method effective to detection of locating of them
Primary Subject
Source
Korean Nuclear Society, Taejon (Korea, Republic of); [CD-ROM]; Oct 2000; [11 p.]; 2000 autumn meeting of the KNS; Taejon (Korea, Republic of); 26-27 Oct 2000; Available from KNS, Taejon (KR); 8 refs, 13 figs
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue