Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.012 seconds
AbstractAbstract
[en] The results of research of a thermalizer (heater) width influence on neutron thermalization efficiency during FCM neutron flux measuring in the 'Ukryttia' are described. The calculations of neutron flux densities were performed by the Monte-Carlo method with the help of computer code MCNP-4C for FCM different models.Three possible installations of detectors were considered: on FCM surface,inside the FCM, and inside the concrete under the FCM layer. It was shown,that in order to increase the sensitivity of neutron detectors in intermediate and fast neutrons field,and consequently, to decrease the dependence of the readings of spectral distribution of neutron flux,it is necessary to position the detector inside the so-called thermalizer or heater. The most reasonable application of thick 'heaters' is the situation, when the detector is placed on FCM surface
Original Title
Ispol'zovanie 'uteplitelej' pri izmerenii nejtronnykh potokov toplivosoderzhashchikh materialov ob'ekta 'Ukrytie'
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Problems of Chernobyl; ISSN 1727-3390;
; (no.12); p. 37-47

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue