[en] The dose distribution around an intravascular brachytherapy 90Y line source with centering balloon catheters was measured with a plastic scintillator, TLD and radiochromic film. The absolute dose rates measured with the three detectors in a solid water phantom at 1, 2 and 3 mm distance from the centering balloon surfaces are in agreement within 3.5%, when the detectors are calibrated with the same 90Sr/90Y source. The dose rates measured with the plastic scintillator in the solid water phantom are in agreement with those directly measured in water. The measured relative dose distributions can be reproduced by Monte Carlo calculations. Also, the influence of the balloon diameter on the dose rate can be reproduced by the calculations. The dose rate calibration routinely performed with the plastic scintillator was checked for fifty-one sources with a well chamber and with another dedicated dose rate checking device. These measurements show that the consistency of the calibration of these sources was better than 10%. In a previous paper absolute dose rates for five other 90Y sources measured with TLD and radiochromic film in a solid water phantom were compared with those obtained with the plastic scintillator in water [Piessens and Reynaert, ''Verification of absolute dose rates for intravascular beta sources,'' Phys. Med. Biol. 45, 2219-2231 (2000)]. Differences of 25 to 41%, depending on the balloon diameter, were reported. In this paper we show the evidence for three main reasons for these previously observed discrepancies: an inconsistency between a detector calibration performed with a 6 MeV electron beam and with a calibrated 90Sr/90Y source from NIST (16%), inaccuracies of the measuring distances in the solid water phantom (maximum 7.5%) and a time instability of the plastic scintillator, probably due to radiation damage (6%)
Primary Subject
Secondary Subject
Source
(c) 2002 American Association of Physicists in Medicine.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
ALKALINE EARTH ISOTOPES, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, BETA-PLUS DECAY RADIOISOTOPES, CALCULATION METHODS, DAYS LIVING RADIOISOTOPES, DOSEMETERS, DOSIMETRY, ELECTRON CAPTURE RADIOISOTOPES, ELEMENTS, EVEN-EVEN NUCLEI, HOURS LIVING RADIOISOTOPES, IMPLANTS, INTERMEDIATE MASS NUCLEI, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LUMINESCENT DOSEMETERS, MEASURING INSTRUMENTS, MEDICINE, METALS, NUCLEAR MEDICINE, NUCLEI, ODD-ODD NUCLEI, RADIATION SOURCES, RADIOISOTOPES, RADIOLOGY, RADIOTHERAPY, SECONDS LIVING RADIOISOTOPES, STRONTIUM ISOTOPES, TECHNETIUM ISOTOPES, THERAPY, TRANSITION ELEMENTS, YEARS LIVING RADIOISOTOPES, YTTRIUM ISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
External URLExternal URL