[en] Current Latvian regulations encourage re-export of DSS, however, up to now in the repository has been disposed a lot of DSS. Baldone repository has received RW (mainly DSS) from ∼ 300 Latvia objects and from Kaliningrad region (from 1964 to 1973). DSS cause the major part of activity of the repository - from the total activity in facility ∼ 400 TBq more than 300 TBq is due to DSS. A long term Safety Assessment (SA) of the Baldone Radon-type near surface disposal facility has been performed by the consortium CASSIOPEE and recommendations are given. The waste disposal system consists of: vaults 1-6 (closed, as permanent disposal site), vault 7 (as a long-term retrievable storage site); 2 main components of the engineered barriers: the capping system and the vaults. Vaults 1 and 3-6 (of re-fabricated concrete elements, closed with reinforced concrete slabs, covered with hydro isolating layer completed by a sand/ soil layer). The vault No.7 (ten 130 m3 underground concrete walled storage cells, protected from the weather by the building. These 10 underground storage cells are adjacent (2x5) with additional concrete walls in some of them. The cells are covered by 40 cm concrete slabs placed side to side. The assessment context and development of scenarios are presented in the paper. The results from the SA are presented. For the waste pathway scenarios - the resulting doses - ∼ 4 mSv/y at 30 y in the current status without cover, justify the implantation of a cover for the closure period of the repository. For air pathway scenarios - the basic dose target 1 mSv/y (for public) is not satisfied for all scenarios; the resulting effective dose for the on-site 'Western' residential scenario for the vaults with highest content of DSS: vault 3 - 303 mSv/y; vault 7 - 204 mSv/y. The main recommendations from the SA are: General Advice - to dispose sources with half-lives < 5,3 y; for the spent sources - to build a new long-term storage; 2. To move DSS from Vault 7 to the long-term storage; 3. To dispose only those sources capable to decay during functioning of disposal site. 4. To revise and update Waste Acceptance Criteria (WAC), especially for disused sealed sources. 5. To build a 5 m thick cap over the vaults. The activity related criteria and predisposal packing of DSS are presented. The problems and solutions for the construction of new storage and disposal spaces are discussed
Primary Subject
Source
2003; 50 p; IAEA Regional workshop on safety considerations of disposal of disused sealed sources in nuclear surface facilities; Sofia (Bulgaria); 1-5 Dec 2003
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue