Seo, B.-K.; Lee, K.-W.; Woo, Z.-H.; Jeong, K.-S.; Oh, W.-Z.; Han, M.-J.
Proceedings of the 5th International Conference: Nuclear Option in Countries with Small and Medium Electricity Grids2004
Proceedings of the 5th International Conference: Nuclear Option in Countries with Small and Medium Electricity Grids2004
AbstractAbstract
[en] Measurement of the surface contamination by an indirect method is subject to the various kinds of error according to the sampling person and needs much time and effort in the sampling and assay. In this research, an automatic smear sampler is developed. It improved efficiency for assay work of surface contamination level achieved periodically in a radiation controlled area. Using an automatic smear sampler developed, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. Also, Solid scintillation proximity membranes were prepared for measuring the amount of radioactive contamination in laboratories contaminated by the low energy beta-ray emitter, such as 3H and 14C. Polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The inorganic fluor-impregnated membranes were applied to detect the radioactive surface contamination. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent in the solution with non-solvent in a coagulation bath. The prepared membranes had two distinguished, but tightly attached, double layers : one is the supporting layer of dense polymer film and the other results revealed that the prepared membranes were efficient to monitor radioactive contamination with reliable counting ability. For enhancement of pick-up and measurement efficiency, the membrane was prepared with the condition of different membrane solidification. The scintillation produced by interaction with radiation and CAYS was measured with photomultiplier tube. The test results showed that the prepared membranes were efficient to monitor radionuclide-contaminated areas with the good counting ability. Treatment of the polymer film with DMF induced a change in surface morphology which allowed more radioactivity to be transferred from the surface.(author)
Primary Subject
Secondary Subject
Source
Pevec, D.; Debrecin, N. (eds.); Croatian Nuclear Society, Zagreb (Croatia); International Atomic Energy Agency, Vienna (Austria); European Nuclear Society, Brussels (Belgium); 996 p; ISBN 953-96132-8-0;
; 2004; [11 p.]; 5. International Conference: Nuclear Option in Countries with Small and Medium Electricity Grids; Dubrovnik (Croatia); 16-20 May 2004; Available E-mail: bumja@kaeri.re.kr, nkwlee@kaeri.re.kr, woozoohee@hanmail.net, ksjeongl@kaeri.re.kr, wonzin@kaeri.re.kr, mjhan@bear.kyungil.ac.kr

Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CARBON ISOTOPES, CHARGED PARTICLES, CONTAMINATION, ELEMENTS, EVEN-EVEN NUCLEI, HYDROGEN ISOTOPES, IONIZING RADIATIONS, ISOTOPES, LIGHT NUCLEI, METALS, NUCLEI, ODD-EVEN NUCLEI, OXYGEN COMPOUNDS, PHOTOTUBES, RADIATIONS, RADIOISOTOPES, RARE EARTHS, SILICATES, SILICON COMPOUNDS, TRANSITION ELEMENT COMPOUNDS, YEARS LIVING RADIOISOTOPES, YTTRIUM COMPOUNDS