[en] Four operational transients in CANDU-6 RUFIC core have been simulated to assess the adjuster system performance. These transients included startup after a short shutdown, startup after a poison-out shutdown, shim mode operation, and a stepback to 60% full power. Also, an alternative adjuster-banking scheme has been assessed in this report. The alternative adjuster-banking scheme involves rods in Bank 1 and Bank 7 being re-distributed within the two banks. In the alternative adjuster-banking scheme, Bank 1 becomes the heaviest one. The results of the preliminary assessment indicated that the adjuster system as currently designed and installed in the NU core will adequately meet the functional requirements in the RUFIC core. Comparing to the adjuster system performance in the NU core, the total worth of the adjuster in the RUFIC core is reduced, leading to less xenon override capability and shimming capability. However, the overall performance is expected to still be satisfactory. The overall results from the transient studied indicated that the alternative banking scheme does show some better performance characteristics and merits further detailed studies