AbstractAbstract
[en] Irradiation of uranium samples was not done at the RA reactor. Irradiation of fissile materials demands special study as well as safety analysis and safety report. Theoretical studies showed that the temperature of samples could be up to 300 deg C at 6.5 MW reactor power. For that reason it was decided to measure the temperature of capsules containing samples during irradiation which causes problems since they are placed in the core. Temperature dependent on the reactor power was measured by thermocouples and showed that the temperature of the irradiation capsule was 200 deg C at 6.5 MW
Original Title
Proracun i merenje temperature urana pri ozracivanju u eksperimentalnom kanalu reflektora na reaktoru RA
Primary Subject
Source
1964; 5 p; Society for Electronics,Telecommunications, Automation, and Nuclear Engineering; Belgrade (Yugoslavia); ETAN 9. Conference; Zbornik radova 9. Konferencija ETAN-a; Bled (Yugoslavia); Jun 1964; Also available from the Institute of Nuclear Sciences VINCA; 1 refs., 2 figs., 1 tabs
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
ACTINIDES, ELEMENTS, ENRICHED URANIUM REACTORS, HEAVY WATER COOLED REACTORS, HEAVY WATER MODERATED REACTORS, IRRADIATION REACTORS, ISOTOPE PRODUCTION REACTORS, MEASURING INSTRUMENTS, METALS, REACTOR CHANNELS, REACTOR COMPONENTS, REACTOR EXPERIMENTAL FACILITIES, REACTORS, RESEARCH AND TEST REACTORS, RESEARCH REACTORS, TANK TYPE REACTORS, THERMAL REACTORS