[en] In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or precautionary measures), should have assured quality of the used measuring systems. In this respect the findings from this intercomparison exercise are used for an actual control, improvement of the calibration and optimization to ensure the correct application of the used radon measuring systems in Austria. (authors)
Primary Subject
Source
2006; 7 p; Second European IRPA congress on radiation protection - Radiation protection: from knowledge to action; Paris (France); 15-19 May 2006
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
ALKALINE EARTH ISOTOPES, ALPHA DECAY RADIOISOTOPES, CARBON 14 DECAY RADIOISOTOPES, DEVELOPED COUNTRIES, ELEMENTS, EUROPE, EVEN-EVEN NUCLEI, FLUIDS, GASES, HEAVY ION DECAY RADIOISOTOPES, HEAVY NUCLEI, ISOTOPES, NONMETALS, NUCLEI, RADIOISOTOPES, RADIUM ISOTOPES, RARE GASES, WESTERN EUROPE, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue