Rouhani, S.Z.; Becker, K.M.
AB Atomenergi, Nykoeping (Sweden)1963
AB Atomenergi, Nykoeping (Sweden)1963
AbstractAbstract
[en] The present report deals with measurements of void fractions for flow of boiling heavy water in a vertical round duct with 6.10 mm inner diameter and a heated length of 2500 mm. The following ranges of variables were studied and 149 void fraction measurements were obtained. Pressure 7 < p < 60 bars; Steam quality 0 < x < 0.38; Surface heat flux 38 < q/A < 120 W/cm2; Mass velocity 650 < m'/F < 2050 kg/m/s; Void fraction 0. 24 < α < 0.88. The measurements were performed by means of a method, which is based on the (γ, n) reaction, occurring when heavy water is irradiated by gamma rays. The results are presented in diagrams, where the void fractions and the slip ratios are plotted against the steam quality with the pressure as a parameter. The data have been correlated by curves, and the scatter of the data around the curves is less than ± 5 per cent
Primary Subject
Secondary Subject
Source
Sep 1963; 36 p; 6 refs., 15 figs., 1 tab.