[en] In the following study a complete balance over the REFOS receiver module, mounted on the tower power plant CESA-1 at the Plataforma Solar de Almeria (PSA), is carried out. Additionally an error inspection of the various measurement techniques used in the REFOS project is made. Especially the flux measurement system Pro hermes that is used to determine the total entry power of the receiver module and known as a major error source is analysed in detail. Simulations and experiments on the particular instruments are used to determine and quantify possible error sources. After discovering the origin of the errors they are reduced and included in the error calculation. The ultimate result is presented as an overall efficiency of the receiver module in dependence on the flux density at the receiver modules entry plane and the receiver operating temperature. (Author) 26 refs