AbstractAbstract
[en] The image quality of proton radiography using the method of beam energy modulation was studied to look into its practical uses. Two different depth-dose distributions generated by modulation were applied to investigate their effects on the density and spatial resolutions of the radiographic image. A steeper slope was found to provide higher resolution for the matching thickness of a phantom. The image was taken on a scintillation screen, and the distance between the phantom and the screen was a sensitive parameter on the resolution. For a beam with a range of 1.2 cm in Lucite, high-resolution images were attainable in the whole range. The resolution of proton images for different kinds of phantoms was examined in comparison with x-ray images as well as images simulated by a Monte Carlo code MCNPX. For a longer range of 18 cm, images attained by simulations indicated that density resolution is better maintained compared to spatial resolution, which is deteriorated by multiple Coulomb scattering
Primary Subject
Source
S0031-9155(08)78582-8; Available from http://dx.doi.org/10.1088/0031-9155/53/19/012; Country of input: International Atomic Energy Agency (IAEA)