AbstractAbstract
[en] Proposed is a method for better estimation of effective dose E based on readouts of personal dosemeter calibrated in terms of personal dose equivalent Hp(10). This method uses data on anisotropy of workplace radiation fields and parameters of distributions of conversion coefficient between Hp(10) and E. Distributions of conversion coefficients for a randomly oriented phantom were obtained by stochastic simulation for several ranges of anisotropy factor introduced for classification of workplaces. The 95 percentile of the conversion coefficient distribution applied to Hp(10) is proposed as the reasonably conservative approximation of the effective dose for moderately anisotropic photon fields
Primary Subject
Source
SSD15: 15. solid state dosimetry conference; Delft (Netherlands); 8-13 Jul 2007; S1350-4487(08)00019-X; Available from http://dx.doi.org/10.1016/j.radmeas.2008.01.007; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)