AbstractAbstract
[en] The mass attenuation coefficients for Cd, Se, Te in elemental state and semiconductor CdSe, CdTe were measured at different energies from 9.7 to 87.3 keV by using the secondary excitation method. These energies were obtained using secondary targets such as Br, Sr, Mo, Cd, In, Sn, Sb, La, Eu, Tb, Yb, W, Au, Hg, Tl, Pb, and Bi. These secondary targets were excited with 241Am and 57Co annular radioactive sources. X-rays emitted from secondary targets were counted by an Ultra-LEGe detector with a resolution of 0.15 keV at 5.9 keV. Effective atomic numbers and their variation with photon energy in CdSe and CdTe semiconductors were discussed. Experimental mass attenuation coefficient values were compared with theoretical values obtained using XCOM
Primary Subject
Source
S1350-4487(08)00086-3; Available from http://dx.doi.org/10.1016/j.radmeas.2008.03.033; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
ACTINIDE NUCLEI, ALPHA DECAY RADIOISOTOPES, AMERICIUM ISOTOPES, BETA DECAY RADIOISOTOPES, CADMIUM COMPOUNDS, CHALCOGENIDES, COBALT ISOTOPES, DAYS LIVING RADIOISOTOPES, ELECTRON CAPTURE RADIOISOTOPES, ENERGY-LEVEL TRANSITIONS, HEAVY NUCLEI, INTERMEDIATE MASS NUCLEI, ISOTOPES, MATERIALS, NUCLEI, ODD-EVEN NUCLEI, RADIOISOTOPES, SELENIDES, SELENIUM COMPOUNDS, SPONTANEOUS FISSION RADIOISOTOPES, TELLURIDES, TELLURIUM COMPOUNDS, YEARS LIVING RADIOISOTOPES