[en] The specific total loss of 6.5% silicon content electrical steel, 0.1 mm thick, was measured under sine and pulse width modulation (PWM) excitation conditions. The loss separation is presented in order to assess the effect of high electrical resistivity and the low thickness on the eddy current and excess losses. The hysteresis loss was subdivided into high and low induction and the results were compared to those obtained in 3% SiFe steel. The texture of the samples was measured and discussed relating their effect on the magnetic properties of the material. The results from the texture indicate that its hysteresis loss can be further improved
Primary Subject
Source
8. Latin American workshop on magnetism, magnetic materials and their applications; Rio de Janeiro (Brazil); 12-16 Aug 2007; S0304-8853(08)00188-1; Available from http://dx.doi.org/10.1016/j.jmmm.2008.02.156; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Literature Type
Conference
Journal
Journal of Magnetism and Magnetic Materials; ISSN 0304-8853;
; CODEN JMMMDC; v. 320(14); p. e385-e388