Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.025 seconds
Esteve-Turrillas, Francesc A.; Pastor, Agustin; Guardia, Miguel de la, E-mail: agustin.pastor@uv.es2008
AbstractAbstract
[en] It has been evaluated the use of semipermeable membrane devices (SPMDs) as passive samplers of organophosphorus pesticides from air, in order to determine the contamination of working environments. Additionally, the use of SPMDs as portable samplers has been also considered. The analytical methodology for the determination of diazinon, chlorpyrifos-methyl, pirimiphos-methyl, chlorpyrifos and fenthion in SPMDs exposed to contaminated air was based on microwave-assisted extraction and gas chromatography with mass spectrometry determination. Limit of detection (LOD) values from 2 to 4 ng SPMD-1 and repeatability from 2 to 7% were obtained by using the aforementioned methodology. Theoretical calculated sampling rates were employed for the estimation of the pesticide concentration in air, by using the pesticide mass retained in the deployed SPMD. The obtained LOD values, for a sampling time of 7 days, were from 1 to 2 ng m-3. The evaluation of the air quality of a pesticide laboratory with an intensive use of diazinon and chlorpyrifos has been made in order to check the operation safety conditions
Primary Subject
Source
S0003-2670(08)01356-1; Available from http://dx.doi.org/10.1016/j.aca.2008.07.039; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)