[en] High energy photon beam margin due to a less side scatter and the other things. But there still remains a penumbra where the dose changes rapidly in the region near the edge of a radiation beam, although it is short in width. It is suggested that the width of the penumbra depends on the source size, distance from source to diaphragm, source to skin distance, and depth in tissue. However, it is also supposed that the other factors influence the penumbra width. In this paper, we investigate changes of the physical penumbra widths according to various field sizes and depths, by using the three dimensional dosimetry system. As a result, we found that as field size and depth increase, the physical penumbra width also increases
Primary Subject
Secondary Subject
Source
3 refs, 4 figs
Record Type
Journal Article
Journal
Journal of the Korean Society for Therapeutic Radiology and Oncology; ISSN 1225-6765;
; v. 9(2); p. 333-336

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue