[en] The effect of 100 MeV irradiation of iron ions in p-type gallium antimonide for ion fluences varying from 1 x 1011 to 5 x 1013 cm-2 was investigated using Raman scattering, Fourier transform infrared and X-ray diffraction measurements. Raman spectra showed a strong peak at 232.82 cm-1 (LO) and a weak peak at 223.79 cm-1 (TO). The peaks were shifted towards higher wave number compared to non-irradiated sample indicating the presence of stress in the irradiated samples. The increase of optical absorbance of samples irradiated with different fluences indicates the increase in the amount of disorder and defect concentrations with fluence. The intensity of the XRD peak (2θ = 61.07 degree) of the irradiated samples for (4 0 0) reflections was found to decrease with ion fluence
Primary Subject
Source
18. international conference on ion beam analysis; Hyderabad (India); 23-28 Sep 2007; S0168-583X(08)00171-7; Available from http://dx.doi.org/10.1016/j.nimb.2008.02.027; Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)