[en] The HARP spectrometer that took data at the CERN Proton Synchrotron in 2001 and 2002 had as large-angle detector system a Time Projection Chamber (TPC) surrounded by Resistive Plate Chambers. The design of the TPC, experience with its operation, and its good physics performance are described. The successful recovery from track distortions arising from inhomogeneities of the electric and magnetic fields in the TPC volume is discussed
Primary Subject
Source
S0168-9002(07)02353-4; Available from http://dx.doi.org/10.1016/j.nima.2007.11.025; Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002;
; CODEN NIMAER; v. 588(3); p. 294-317