AbstractAbstract
[en] In our study, we systematically investigated the behavior of charge trapping in P-MOSFETs with HfO2/SiON gate stack. We found that typical linear extrapolation does not work well for the lifetime extraction at normal operation condition since the polarity of dominant trapped charge in high-k dielectric is not the same at lower and higher stress voltage regimes. This phenomenon is considered the competition of hole trapping and electron trapping with respect to applied gate voltages. Besides, the results of AC stress reveal the distinct responses to electrons and holes. It indicates that electrons can easily follow the AC signal while holes seem to need more time for the response at AC stress
Source
IVC-17: 17. international vacuum congress; Stockholm (Sweden); 2-6 Jul 2007; ICSS-13: 13. international conference on surface science; Stockholm (Sweden); 2-6 Jul 2007; ICN+T 2007: International conference on nanoscience and technology; Stockholm (Sweden); 2-6 Jul 2007; Available from http://dx.doi.org/10.1088/1742-6596/100/4/042045; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Literature Type
Conference
Journal
Journal of Physics. Conference Series (Online); ISSN 1742-6596;
; v. 100(4); [4 p.]

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue