Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.02 seconds
Bang, K. S.; Seo, K. S.; Lee, J. H.; Lee, J. C.; Choi, W. S.
Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)2008
Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)2008
AbstractAbstract
[en] This is technical report conducted by KAERI under the contract with NETEC for safety test for the PWR S/F dry storage system. Leak Test was performed after drop test and turn-over test, the measured leakage rate was lower than allowable leakage rate. It is revealed that the containment integrity of the dry storage system is maintained. In the seismic test, the moving of the model was measured at SRTH seismic response of 0.4 g and 0.8 g. Therefore the seismic test results can be used fully to the test data for verification of the seismic analysis. In the thermal test, the direction of the inlet and outlet of the air has no effect on the heat transfer performance. The passive heat removal system of the horizontal storage module was designed well
Primary Subject
Source
Nov 2008; 108 p; Also available from KAERI; 88 figs, 35 tabs
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue