Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.013 seconds
AbstractAbstract
[en] After conversion to FLIP fuel at Texas A and M, the fuel temperatures were examined very carefully. It was observed that the fuel temperature at 1 Mw varied over a wide range during the week. This variation was shown to be due to the variation in response of the linear CIC which was used to establish reactor power level. A modification of the linear power monitor was designed and installed. The response of this system was verified by using cobalt wires, fuel temperature, and a fission chamber located at 6 feet from the reactor core. The system has proven to be operationally satisfactory. (author)
Primary Subject
Source
General Atomic Co., San Diego, CA (United States); 432 p; 1974; p. 2.69-2.76; 3. TRIGA owners' conference; Albuquerque, NM (United States); 25-27 Feb 1974; Country of input: International Atomic Energy Agency (IAEA); 1 ref, 8 figs
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue