Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.018 seconds
AbstractAbstract
[en] A survey was conducted to estimate the average glandular dose (Dg) for patients undergoing mammography and to report the distribution of incident air kerma (Ki), patient age, compressed breast thickness and glandular tissue content. From 1183 cranio caudal mammograms clinical data were collected and doses were measured. The survey data included mammograms from six mammography equipment: two screen/film units (SFM), two computed radiography units (CR) and two full-field digital (DR). Mean value for patient age and compressed breast thickness were 57 +-12 y and 5.4 +-1.4 cm, respectively. To investigate the importance of technical characteristics of three different mammography systems and breast glandularity, Ki and Dg were measured for individual breast of 392 patients from the original sample with compressed breast thickness in the range of 5.5 cm to 6.5 cm using tissue-equivalent phantoms of different glandularities manufactured in this study to mimic both the attenuation and the density of breast tissues. Mean Ki value was 10.0 +-3.6 mGy for SFM systems, 12.0 +-3.6 mGy for CR systems and 4.9 +-1.3 mGy for DR systems. Mean Dg value was 1.4 +-0.5 mGy for S/F systems, 1.7 +-0.5 mGy for CR systems and 0.9 +-0.2 mGy for D R systems. Statistical analysis for differences in mean values of Ki and Dg between mammography systems showed significant effect of their technical characteristics (p < 0.05). In regard to the influence of glandular tissue content in Ki and Dg, it was observed statistically significant differences between the group of patients with 0 to 50% glandularity and the group of patients with 50 to 100% glandularity. (author)
Original Title
Avaliacao da dose glandular em sistemas de mamografia convencional e digital utilizando um fantoma dosimetrico
Primary Subject
Source
2009; 129 p; 88 refs., 26 figs., 23 tabs.; Tese (Ph.D.)
Record Type
Miscellaneous
Literature Type
Thesis/Dissertation
Report Number
Country of publication
BIOLOGICAL MODELS, BIOMEDICAL RADIOGRAPHY, CHEST, COMPUTERIZED TOMOGRAPHY, DEPTH DOSE DISTRIBUTIONS, DOSE EQUIVALENTS, DOSE RATES, DOSIMETRY, FUNCTIONAL MODELS, IONIZATION, ISODOSE CURVES, KERMA, KINETIC ENERGY, MAMMARY GLANDS, PHANTOMS, RADIATION DOSES, RADIOTHERAPY, TISSUE-EQUIVALENT MATERIALS, X RADIATION, X-RAY RADIOGRAPHY
BODY, DIAGNOSTIC TECHNIQUES, DOSES, ELECTROMAGNETIC RADIATION, ENERGY, GLANDS, INDUSTRIAL RADIOGRAPHY, IONIZING RADIATIONS, MATERIALS, MATERIALS TESTING, MEDICINE, MOCKUP, NONDESTRUCTIVE TESTING, NUCLEAR MEDICINE, ORGANS, RADIATION DOSE DISTRIBUTIONS, RADIATIONS, RADIOLOGY, SPATIAL DOSE DISTRIBUTIONS, STRUCTURAL MODELS, TESTING, THERAPY, TOMOGRAPHY
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue