[en] The 126-B-2, 183-B Clearwells were built as part of the 183-B Water Treatment Facility and are composed of 2 covered concrete reservoirs. The bulk of the water stored in the clearwells was used as process water to cool the 105-B Reactor and as a source of potable water. Residual conditions were determined to meet the remedial action objectives specified in the Remaining Sites ROD through an evaluation of the available process knowledge. The results of the evaluation do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also indicate that residual concentrations are protective of groundwater and the Columbia River.