Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.019 seconds
AbstractAbstract
[en] For enhancement of flaw detactability using array transducers, focusing of ultrasonic waves on a target in an inhomogeneous medium or through a complex geometry is important. But focusing can be strongly degraded by geometrical distortion of field radiated by the array transducers or by sound speed fluctuations in the propagating medium. In recent years, the time reversal technique has been proposed. Thus, in this paper, we describe the basic principal of the time reversal technique for focusing. Then, the implementation results of the time reversal technique for ultrasonic inspections using bulk waves and guided waves generated by array transducers are presented
Primary Subject
Source
8 refs, 10 figs
Record Type
Journal Article
Journal
Journal of the Korean Society for Nondestructive Testing; ISSN 1225-7842;
; v. 26(3); p. 190-197

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume