[en] In this work the measurement of the dead time of the neutron detection initiation chains of the RP-0 and RP-10 nuclear reactors is presented. Those reactors have proportional detector (BF3) and ionization chamber fission (CF) respectively. The determination is based on the model non-paralizable detector. The reactor varies on time in an exponential way right after a little insertion of positive reactivity and it was used like a source of neutrons. The nonlinear adjustment to the model allowed the determination of the dead time through minimization of the Chi square. The obtained values were BF3: 19.96 x 10-6s ± 0.02 x 10-6s and CF: 2.52 x 10-6s ± 0.01 x 10-6s (orig.)
Original Title
Determinacion del tiempo muerto de la cadena de arranque de un reactor nuclear
Primary Subject
Secondary Subject
Source
Prado Cuba, A.; Santiago Contreras, J.; Rojas Tapia, J.; Ramos Trujillo, B.; Vela Mora, M.; Castro Gamero, E. (Instituto Peruano de Energia Nuclear, Lima (Peru)) (eds.), E-mail: aprado@ipen.gob.pe; Instituto Peruano de Energia Nuclear (IPEN), Lima (Peru); 338 p; ISSN 1684-1662;
; Apr 2010; p. 123-130; Also available from the Library of the Peruvian Institute of Nuclear Energy in electronic format (pdf); 10 refs., 14 figs.