Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.017 seconds
Palomo Anaya, M. Jose; Verdu Martin, Gumersindo; Arnaldos Gonzalvez, Adoracion; Nieva, Marcelino Curiel, E-mail: mpalomo@iqn.upv.es, E-mail: gverdu@iqn.upv.es, E-mail: a.arnaldos@titaniast.com, E-mail: m.curiel@lainsa.com
Associacao Brasileira de Energia Nuclear, Rio de Janeiro, RJ (Brazil)2011
Associacao Brasileira de Energia Nuclear, Rio de Janeiro, RJ (Brazil)2011
AbstractAbstract
[en] This paper is a recompilation of the most significant results in relation to the researching in Preventive and Predictive Maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and The Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the Power Plants Control and Instrumentation Department technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the aim to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish Nuclear Power Plants each of them shall give a significant contribution to problem resolution and power plant performance: Fluctuations in sensor lines (case 1), Air presence in feed water lines (case 2), Root valve partially closed (case 3), Sensor malfunctions (case 4), Electrical source malfunctions (case 5), RTD malfunctions (case 6) and LPRM malfunctions (case 7). (author)
Primary Subject
Source
2011; 11 p; INAC 2011: International nuclear atlantic conference. Nuclear energy: new jobs for a better life; Belo Horizonte, MG (Brazil); 24-28 Oct 2011; 17. ENFIR: Meeting on nuclear reactor physics and thermal hydraulics; Belo Horizonte, MG (Brazil); 24-28 Oct 2011; 10. ENAN: Meeting on nuclear applications; Belo Horizonte, MG (Brazil); 24-28 Oct 2011; 2. ENIN: Meeting on nuclear industry; Belo Horizonte, MG (Brazil); 24-28 Oct 2011
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue