AbstractAbstract
[en] In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams. (author)
Original Title
Avaliacao dosimetrica da solucao Fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimentria de eletrons e neutrons
Primary Subject
Secondary Subject
Source
2009; 78 p; Diss. (M.Sc.)
Record Type
Miscellaneous
Literature Type
Thesis/Dissertation; Numerical Data
Report Number
Country of publication
BEAMS, COLLOIDS, DATA, DISPERSIONS, DOSEMETERS, DOSES, DOSIMETRY, ELEMENTARY PARTICLES, ELEMENTS, FERMIONS, INFORMATION, LEPTON BEAMS, LEPTONS, MEASURING INSTRUMENTS, MEDICINE, NEUTRON THERAPY, NUCLEAR MEDICINE, NUCLEON BEAMS, NUMERICAL DATA, PARTICLE BEAMS, RADIOLOGY, RADIOTHERAPY, SEMIMETALS, SPECTRA, THERAPY
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue