[en] The operational problems of the gamma ray spectrometer shielded passively with 12 cm of lead and actively by five 0.5 m × 0.5 m × 0.05 m plastic veto shields are described. The active shielding effect from both environmental gamma ray, cosmic muons and neutrons was investigated. For anticoincidence gating wide range of scintillator pulses, corresponding to the energy range of 150 keV-75 MeV, were used. With the optimal set up the integral background, for the energy region of 50 - 3000 keV, of 0.31 c/s was achieved. The detector mass related background was 0.345 c/(kg s). The 511 keV annihilation line was reduced by the factor of 7 by the anticoincidence gate. It is shown that the plastic shields increase the neutron capture gamma line intensities due to neutron termalization.(author)
Primary Subject
Source
Knezevic, Z.; Krajcar Bronic, I.; Majer, M. (eds.); 578 p; ISBN 978-953-96133-8-7;
; 2013; p. 508-513; 9. Symposium of the Croatian Radiation Protection Association; Krk (Croatia); 10-12 Apr 2013; 11 refs., 1 tab., 3 figs.