Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.016 seconds
Gonzalez M, J. L.; Rivero G, T.; Sainz M, E., E-mail: joseluis.gonzalez@inin.gob.mx
Sociedad Nuclear Mexicana (SNM), Mexico D. F. (Mexico); Sociedad Mexicana de Seguridad Radiologica (SMSR), Mexico D. F. (Mexico). Funding organisation: GE, Energy (United States); Toshiba (Mexico); Westinghouse (United States); Tenex (Russian Federation); Nukem (Germany); Vertek Industrial Supply Inc. (United States); Grupo IAI (Mexico); Tecnatom (Spain); Iberdrola, Ingenieria y Construccion (Spain)2014
Sociedad Nuclear Mexicana (SNM), Mexico D. F. (Mexico); Sociedad Mexicana de Seguridad Radiologica (SMSR), Mexico D. F. (Mexico). Funding organisation: GE, Energy (United States); Toshiba (Mexico); Westinghouse (United States); Tenex (Russian Federation); Nukem (Germany); Vertek Industrial Supply Inc. (United States); Grupo IAI (Mexico); Tecnatom (Spain); Iberdrola, Ingenieria y Construccion (Spain)2014
AbstractAbstract
[en] Due to the obsolescence of the instrumentation and control system of the nuclear research reactor IAN-R1, the Institute of Geology and Mining of Colombia, IngeoMinas, launched an international convoking for renewal it which was won by the Instituto Nacional de Investigaciones Nucleares (ININ). Within systems to design, the reactor protection system is described as important for safety, because this carried out, among others two primary functions: 1) ensuring the reactor shutdown safely, and 2) controlling the interlocks to protect against operational errors if defined conditions have not been met. To fulfill these functions, the various subsystems related to the safety report the state in which they are using binary signals and are connected to the inputs of two redundant logic wiring circuits called action logics (Al) that are part of the reactor protection system. These Al also serve as logical interface to indicate at all times the status of subsystems, both the operator and other systems. In the event that any of the subsystems indicates a state of insecurity in the reactor, the Al generate signals off (or scram) of the reactor, maintaining the interlock until the operator sends a reset signal. In this paper the design, implementation, verification and testing of circuits that make up the Al 1 and 2 of IAN-R1 reactor is described, considering the fulfillment of the requirements that the different international standards imposed on this type of design. (Author)
Original Title
Diseno de los circuitos de la logica de actuacion del sistema de proteccion del reactor nuclear IAN-R1 de Colombia
Primary Subject
Secondary Subject
Source
Oct 2014; 14 p; Sociedad Nuclear Mexicana; Mexico D. F. (Mexico); 25. SNM Annual Congress; 25. Congreso Anual de la SNM; Boca del Rio, Veracruz (Mexico); 31 Aug - 4 Sep 2014; 13. SMSR National Congress: the nuclear challenges; 13. Congreso Nacional de la SMSR: los retos nucleares: extension de vida, seguridad, percepcion publica y reactores de nueva generacion; Boca del Rio, Veracruz (Mexico); 31 Aug - 4 Sep 2014; life extension, safety, public perception and reactors of new generation; 13. Congreso Nacional de la SMSR: los retos nucleares: extension de vida, seguridad, percepcion publica y reactores de nueva generacion; Boca del Rio, Veracruz (Mexico); 31 Aug - 4 Sep 2014; Available from the Instituto Nacional de Investigaciones Nucleares, Centro de Informacion y Documentacion, 52750 Ocoyoacac, Estado de Mexico (MX), e-mail: mclaudia.gonzalez@inin.gob.mx
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
COLOMBIAN ORGANIZATIONS, DESIGN, DEVELOPING COUNTRIES, ENGINEERED SAFETY SYSTEMS, ENRICHED URANIUM REACTORS, IRRADIATION REACTORS, ISOTOPE PRODUCTION REACTORS, LATIN AMERICA, NATIONAL ORGANIZATIONS, POOL TYPE REACTORS, REACTOR SHUTDOWN, REACTORS, RESEARCH AND TEST REACTORS, RESEARCH REACTORS, SHUTDOWN, SOUTH AMERICA, THERMAL REACTORS, TRAINING REACTORS, WATER COOLED REACTORS, WATER MODERATED REACTORS
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue