Horie, Y; Shiotsu, M; Shirai, Y; Higa, D; Shigeta, H; Tatsumoto, H; Naruo, Y; Nonaka, S; Kobayashi, H; Inatani, Y, E-mail: shiotsu@pe.energv.kyoto-u.ac.jp2015
AbstractAbstract
[en] Forced flow heat transfer of hydrogen from a round wire in a vertically-mounted pipe was measured at pressure of 1.5 MPa and temperature of 21 K by applying electrical current to give an exponential heat input (Q=Q_0exp(t/τ),τ=10 s) to the round wire. Two round wire heaters, which were made of Pt-Co alloy, with a diameter of 1.2 mm and lengths of 54.5 and 120 mm were set on the central axis of a flow channel made of FRP with inner diameter of 5.7 and 8.0 mm, respectively. Supercritical hydrogen flowed upward in the channel. Flow velocities were varied from 1 to 12.5 m/s. The heat transfer coefficients of supercritical hydrogen were compared with the conventional correlation presented by Shiotsu et al. It was confirmed that the heat transfer coefficients for a round wire were expressed well by the correlation using the hydraulic equivalent diameter. (paper)
Source
Cryogenic engineering conference (CEC) 2015; Tucson, AZ (United States); 28 Jun - 2 Jul 2015; Available from http://dx.doi.org/10.1088/1757-899X/101/1/012176; Country of input: International Atomic Energy Agency (IAEA)