Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.029 seconds
Ravikumar Pandi, V.; Al-Hinai, A.; Feliachi, Ali, E-mail: vpandi@masdar.ac.ae2015
AbstractAbstract
[en] Highlights: • We aims to maintain feeder power flow by the coordination of DER units. • The error in feeder flow with respect to scheduled value is used by the controller. • The particle swarm optimization is employed to minimize the error in feeder flow. • Implemented on a transmission system along with 37 bus distribution feeder. • The results of proposed feeder control is analyzed with no feeder control scheme. - Abstract: The control of generating resources to follow the unscheduled load changes is considered to be an essential process in the power system in order to maintain the frequency of power supply. This load frequency control (LFC) problem has been given more importance in the recent smart grid environment because of the impact from high penetration of distributed energy resources (DER) installed at the distribution level. The renewable sources are highly intermittent in nature, so it is required to coordinate and control the DER units to maintain the feeder power flow at substation bus bar which is seen by transmission system operator during the LFC process. This paper aims to identify the impact of distributed generation and its control method to reduce the deviation of feeder power flow from the scheduled value in real time operation. The error in feeder power flow with respect to scheduled value is utilized by the PI controller to estimate the change in power reference of all DER units. The power output of DER units are maintained to reference values by the individual PI controllers. The particle swarm optimization algorithm is employed to minimize the error in feeder power flow by optimally tuning the gain values of all PI controllers. The proposed method is examined on a small transmission system along with the feeder of IEEE 37 bus distribution system with balanced loading condition. The complete system along with DER units is implemented in the MATLAB based stability package named Power Analysis Toolbox (PAT) for performing time domain analysis. The impact on feeder flow and system frequency for the disturbance in load and weather condition without feeder control scheme (NFC) is compared with the feeder control scheme (WFC).
Primary Subject
Source
S0196-8904(15)00800-6; Available from http://dx.doi.org/10.1016/j.enconman.2015.08.046; Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue