[en] Highlights: • Pool temperature effects on the FP removal were not clearly concluded in the previous publications. • It was confirmed that the removal efficiency decreased with temperature around the boiling point. • A modified empirical formula for FP removal was proposed as a function of sub-cooling temperature. • DF could be predicted with an accuracy within a factor of 2 with the proposed formula. - Abstract: The wet-well of boiling water reactors plays important roles not only to suppress the pressure in the primary containment vessel due to steam scrubbing effects during severe accidents but also to mitigate release of radioactive fission products (FP), aerosols and particulates, into the environment. The effects of steam scrubbing in the wet-well on FP removal have been well studied and reported by changing major parameters determining the removal efficiencies, e.g., aerosol diameters, submergence (depth of scrubbing nozzles) and steam/non-condensable gas volume fraction. Unfortunately, the effects of pool temperature on the FP removal were not clearly concluded in the previous publications, though it would be easily expected that boiling in the pool resulted in reduced aerosol removal efficiency. In order to determine the temperature effects on FP removal efficiency, amounts of cesium in aerosols released from scrubbing pool were measured by changing pool temperature in mini and medium scale scrubbing experiments, and then, it was confirmed that the removal efficiency clearly decreased with temperature around the boiling point. Then, a modified empirical formula to express the FP removal around the boiling point temperature was proposed as a function of sub-cooling temperature by applying the effective steam volume fraction, which was designated as the volume ratio of condensed steam in the pool versus the sum of input steam and non-condensable gas. By comparing the measured removal efficiency with the calculated, it was validated that the decontamination factor (DF) could be predicted with an accuracy within a factor of 2 with the proposed formula.
Primary Subject
Secondary Subject
Source
S0029-5493(16)00012-1; Available from http://dx.doi.org/10.1016/j.nucengdes.2016.01.002; Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
ALKALI METALS, CLEANING, COLLOIDS, DISPERSIONS, ELEMENTS, ENRICHED URANIUM REACTORS, EVALUATION, ISOTOPES, MATERIALS, METALS, NUCLEAR FACILITIES, PARTICLES, PHASE TRANSFORMATIONS, PHYSICAL PROPERTIES, POWER PLANTS, POWER REACTORS, RADIOACTIVE MATERIALS, REACTORS, REMOVAL, SOLS, SURFACE WATERS, THERMAL POWER PLANTS, THERMAL REACTORS, THERMODYNAMIC PROPERTIES, TRANSITION TEMPERATURE, WATER COOLED REACTORS, WATER MODERATED REACTORS
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue