Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.015 seconds
Pillon, Mario; Monti, Chiara; Mugnaini, Giampiero; Neri, Carlo; Rossi, Paolo; Carta, Mario; Fiorani, Orlando; Santagata, Alfonso, E-mail: mario.pillon@enea.it2015
AbstractAbstract
[en] Highlights: • Piezoceramic motors are compliant with magnetic field, temperature and vacuum. • We studied the response of a piezoceramic motor during the irradiation with neutrons. • The response was studied using 1 MeV neutrons up to a neutron fluence of 2.77E+17 n/cm"2. • Neutron irradiation produces a shift of the optimal resonance frequency and a decrease of the motor speed. • The performance changes do not affect the proper operation of the motor. - Abstract: A piezoceramic motor has been identified as the potential apparatus for carrying out the rotation of the scanning head of a laser radar system used for viewing the first wall of the ITER vessel. This diagnostic is simply referred to as IVVS (In Vessel Viewing System). The choice fell on a piezoceramic motor due to the presence of strong magnetic fields (up 8 T) and of the high vacuum and temperature conditions. To be compliant with all the ITER environmental conditions it was necessary to qualify the piezo-motor under gamma and neutron irradiation. In this paper are described the procedures and tests that have been performed to verify the compatibility of the operation of the motor adopted in the presence of a fast neutron fluence which was gradually increased over time in order to reach a total value of 2.77 × 10"1"7 n/cm"2. Such neutron fluence was obtained by irradiating the motor in a position close to the core of the fast nuclear reactor TAPIRO, in operation at the ENEA Casaccia Research Centre, Italy. The neutron spectrum in this position has been identified as representative of that found in the rest position of the IVVS head during ITER operation. The cumulative neutron fluence reached corresponds to that it is expected to be reached during the entire life of ITER for the IVVS in the rest position without any shield. This work describes the experimental results of this test; the methodology adopted to determine the total neutron fluence achieved and the methodology adopted for the verification of the correct operation of the motor.
Primary Subject
Source
SOFT-28: 28. symposium on fusion technology; San Sebastian (Spain); 29 Sep - 3 Oct 2014; S0920-3796(15)00183-0; Available from http://dx.doi.org/10.1016/j.fusengdes.2015.03.025; Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Literature Type
Conference
Journal
Country of publication
BARYONS, CLOSED PLASMA DEVICES, ELEMENTARY PARTICLES, ENERGY RANGE, ENGINES, EPITHERMAL REACTORS, FERMIONS, HADRONS, ITALIAN ORGANIZATIONS, NATIONAL ORGANIZATIONS, NEUTRONS, NUCLEONS, PRESSURE RANGE, REACTORS, SPECTRA, THERMONUCLEAR DEVICES, THERMONUCLEAR REACTOR WALLS, THERMONUCLEAR REACTORS, TOKAMAK DEVICES, TOKAMAK TYPE REACTORS
Reference NumberReference Number